"Metro Plaza", 3rd & 4th Floor, E-5 Arera Colony, Bittan Market, Bhopal – 462  016

 
 

 

Tariff Schedule – LV - 4

WATER WORKS :

 

 

WATER WORKS :

1              Applicability

This tariff is applicable for Public Utility Water Supply Schemes, sewage treatment plants and Sewage Pumping Installations run by P.H.E. Department, Local Bodies and Gram Panchayats or any  organization made responsible by the Government to supply/ maintain public water works / Sewerage Installations.

2              Character of service:

 Alternating Current, 50 cycles, three phase, 400 Volts or above depending upon the availability of voltage of supply.

           Point of Supply:

Energy will be supplied to the consumer at a single point. 

TOP

4             Tariff:

 

Category of consumers

Fixed Charges

 

Energy Charges

paise per unit 

 

 

 

 

 

LV-4

 

 

4.0

Water Works:

 

 

 4.1

Municipal Corporation/ Cantonment Boards

NIL

300

 4.2

Municipality/ Nagar Panchayat

NIL

270

 4.3

Gram Panchayat

NIL

245

5                 Minimum Charge:

Charges equivalent to 30 unit per month per HP or  part thereof  of the connected load shall be payable by Consumers.

6                Billing in case of defective meters

The consumer shall be billed for the period, when the meter has become defective, on the basis of average consumption of previous three meter reading cycles.  In cases where the recorded consumption of past three meter reading cycles, prior to the date meter became defective, is either not available or partially available, the consumption pattern of three meter reading cycles subsequent to the installation of repaired/replaced meter shall be taken for estimation of consumption.  This charge shall be levied till the meter is repaired/replaced and metering restored on the actual consumption basis.

TOP

7                 Rounding off

All bills will be rounded off to the nearest rupee.

8                 Other Terms and Conditions

a)      Late payment Surcharge: If the bills are not paid by the consumers within the period (due date) prescribed, a surcharge of 1.5% per month of the total amount of monthly bill (including outstanding arrears) will be payable in addition.

b)      Fuel/ Variable Cost Adjustment (VCA) Charge: Fuel charge/ VCA charge, if any, shall be levied  in addition to energy charge. 

c)      Meter Hire – Meter Hire shall be charged as per the Schedule of Miscellaneous Charges. Part of a month will be reckoned as full month for purpose of billing.

d)      Ordinarily, no new supply to LT installations with induction motor(s) of capacity of 3 HP and above will be given unless suitable capacitors to improve the power factor, are installed.

e)      The  consumers under the foregoing tariffs, shall maintain an average power factor not less than 0.8 in any month.

f)        Every power consumer  whose connected load includes induction motor/s of capacity of 3 HP and above, shall arrange to install Low Tension Shunt  Capacitors at his cost across the terminals of his motors of the rating specified herein below:-

              

Sl.No.        Rating of individual Induction motor          kVA rating of LT capacitors.

                                    

1.            3 HP and above up to 5 HP                            1

2.            Above 5 HP to 7.5 HP                                    2

3.            Above 7.5 HP to 10 HP                                  3

4.            Above 10 HP to 15 HP                                   4

5.            Above 15 HP to 20 HP                                   5

6.            Above 20 HP to 30 HP                                   6 

7.            Above 30 HP to 40 HP                                   7

8.            Above 40 HP to 50 HP                                    8

9.            Above 50 HP to 100 HP                                   9

g)      The decision of the Executive Engineer of the Board as to the adequacy or otherwise of the power factor improvement device installed shall be binding on consumers. 

h)      Any power consumer who fails to provide LT capacitor of specified rating  or any consumer to whom supply is given without his  installing capacitor  of specified rating,  shall be liable to pay power factor surcharge of 26 (twenty six) paise per unit in respect of consumption of the entire installation during the month.

i)        The power factor surcharge shall be applicable to the entire monthly consumption of the installation.

j)        Levy of power factor surcharges as indicated herein shall be without prejudice to the rights of the Board to disconnect the consumer’s installation, if steps are not taken to improve the power factor by installing suitable shunt capacitors.

k)      The foregoing tariffs  are applicable to the extent of the connected load for which the agreement subsists between the Board and the consumer. In case the connected load in the consumer’s premises  is at any time found in excess of what has been agreed to between the consumer  and the Board, the consumer shall have to pay in respect of units (including minimum charge) corresponding to the excess load at 1.5 times the normal tariff rate (inclusive of Fuel/ Variable Cost Adjustment Charge, if any), for previous three months immediately preceding the date of inspection, unless the onus is rebutted by the consumer.

l)        The foregoing tariffs are applicable to  connections having connected load not exceeding 100 HP . Consumers having existing load in excess of 100 HP are allowed time till 30th June, 2003 for conversion of their connection from LT to HT supply. Such consumers will have to pay Transformer rent and 3% losses separately upto the time the transformer is installed by the consumer. In future if any consumer is found having connected load more than 100 HP , the consumer will be required to convert to HT within six months from date of checking.

m)    In case of any dispute on applicability of tariff on a particular LT category, the decision of the Commission shall be final and binding.

n)      The tariff does not include any tax or duty, etc. on electrical energy that may be payable at any time in accordance with any law then in force. Such charges, if any, shall be payable by the consumer in addition to the tariff charges.  

o)      Notwithstanding the provisions, if any, contrary to the agreement entered into by the consumer with the Board, all conditions prescribed herein shall be applicable to the consumer.

 PREVIOUS |TOP| NEXT